Features & Benefits:
Maintenance
- Low capital cost and minimal maintenance requirements lead to lowest cost of ownership.
- Extended periods between user intervention.
- Lower consumable costs.
Environmental
- No oil disposal.
- No oil emissions into atmosphere.
Performance
- Very stable pumping speed gives repeatability to processes.
- Continuous pumping at atmosphere.
- Ability to handle particulates.
- Dry eliminates back-streaming, thus protecting reactive alloys from contamination.
Safety
- Unobtrusive noise levels.
- No unsightly oil spills.
- No hazardous oil vapours.
Technical Data:
| Units | GXS250 | GXS250/2600 | |||
| Peak Pumping Speed | m3h-1 (cfm) | 250 (147) | 1900 (1118) | ||
| Ultimate Pressure (without purge) | mbar (Torr) | 4x10-3 (3.0x10-3) | 5x10-4 (3.8x10-4) | ||
| Full Load Power | @ ultimate pressure | kW (hp) | 4.0 (5.4) | 5.3 (7.1) | |
| @ peak pumping load | kW (hp) | 9.0 (12.1) | 9.7 (13.0) | ||
| Electrical | Supply options | High volt | 380-460V 3Ø 50/60Hz | ||
| Low volt | 200-230V 3Ø 50/60Hz | ||||
| Connection | High volt | Harting Han K 4/4-F | |||
| Low volt | |||||
| Vacuum Couplings | Inlet | ISO63 | ISO160 | ||
| Exhaust | NW40 | ||||
| Cooling Water | Supply pressure (max) | bar (psig) | 6.9 (100) | ||
| DP across pump (min) | bar (psig) | 1.0 (14.7) | |||
| Flow @ min DP | lmin-1 (gal/min) | 4.0 (1.1) | 7.0 (1.9) | ||
| Temperature | °C (°F) | 5-40 (41-104) All variants | |||
| Connection | 3/8" BSP Male (G 3/8”) | ||||
| Purge Gas* | Pressure | bar (psig) | 2.5-6.9 (36-100) | ||
| Light Duty | sl/min | 12 | |||
| Medium Duty | sl/min | 18-52 | |||
| Connection | Swagelok® Ø ¼” tube with olive | ||||
| High Flow Purge/ Solvent Flush | Supply pressure | bar (psig) | 2.5-6.9 (36-100) | ||
| Control valve connection | Swagelok® Ø 3/8" tube with olive | ||||
| Filter connection | ½" NPT Male | ||||
| Solvent connection | 3/8" BSP Male (G 3/8") | ||||
| Mass | kg (lbs) | 305 (672) | 515 (1035) | ||
| Noise (with suitable exhaust pipe) | dB(A) | <64 | |||
| Operating Temperature | °C (°F) | 5-40 (41-104) | |||
| Exhaust Back Pressure (MAX) | mbar (psia) | 1400 (20) | |||
| System IP rating | Standard | 31 | |||
| Lubrication | Type | PFPE Drynert® 25/6 | |||
| Volume | l (gal) | 0.7 (0.2) | 1.4 (0.4) | ||
|
Monitoring & Control |
Standard | Control |
Front panel "Dashboard" Serial - RS232 |
||
| Monitoring | Ethernet Webserver | ||||
| Option | Control | Parallel - MCM MicroTIM | |||
| Control & Monitoring |
Profibus DP Pump Display Terminal (PDT) |
||||
| Monitoring | FabWorks® | ||||
| *Pump combinations | Light duty | Shaft Seal Purge only | |||
| Medium duty | Shaft Seal Purge, High Vac Purge, Inlet Purge, variable Gas Ballast & Exhaust Purge (with Exhaust Pressure Sensor) | ||||
| Medium duty + | As Medium duty, plus High Flow Purge / Solvent Flush | ||||
* Purge Gas information
Light duty: shaft seal purge only
Medium duty: Shaft seal purge, inlet purge, variable gas ballast & exhaust purge (with exhaust pressure sensor)
Medium duty plus: As Medium duty, plus High Flow Purge / Solvent Flush
Inquiry -